MATERIAL SAFETY DATA SHEET

 

Wausau Chemical Corporation, 2001 N. River Drive, Wausau, WI 54403

                                                                             Last Revision:               January 27, 2004

HMIS Hazard

4 – Extreme                  Health              0

3 – High                       Fire                  2

2 – Moderate               Reactivity         0

1 – Slight                      Other

0 - Least

 

 
Emergency       CHEMTREC               800-424-9300

Phones:            Wausau Chemical         715-842-2285

SECTION 1 - MATERIAL IDENTIFICATION

 

 

 
 

 

 


NAME:                        GLYCOL ETHER DPM

FORMULA:                CH3O(C3H6O)2 H   M.W.=148.2

SYNONYMS:             Dipropylene glycol monomethyl ether; Propanol, (2-methoxy-methylethoxy)-

MANUFACTURER:   Dow Chemical Company; Eastman Chemical Corp

SECTION 2  - HAZARDOUS INGREDIENTS

 

 
 

 

 


HAZARDOUS CHEMICAL               CAS #             PERCENT       PEL/TWA        SARA III, SEC 313    

Dipropylene glycol monomethyl ether 034590-94-8    99%                   100 ppm                      NO

 

SECTION 3 – CHEMICAL AND PHYSICAL PROPERTIES

 
 

 

 


Appearance:                 Clear, colorless liquid                Boiling Point (oF):                                 374oF

Odor:                           Slight ether                               Melting Point (oF):                                ND

pH:                               NA                                          Specific Gravity (H2O=1 @ 70oF):       0.951

Water solubility:            Infinite                                      Vapor Pressure, mm Hg, 20oC: 0.41

Vapor Density (air=1):  5.14                             Volatile Organic (VOC) content:           100%

Evaporation Rate (Butyl Acetate = 1)                ND

SECTION 4 – FIRE AND EXPLOSION HAZARDS

 

 

 

 

 
 

 


Flash Point (Method):     175oF (Setflash C.C.)            Flammability Limits: Lower       1.10%  Upper  14%

Auto Ignition Temperature:        ND

Extinguishing Media:                 Water spray, dry chemical, carbon dioxide.

 

Special Fire Fighting Procedures and Hazards:  Wear chemical protective clothing and positive pressure self-contained breathing apparatus. Approach upwind to avoid toxic vapors. Avoid applying a direct water stream.

Unusual Fire & Explosion Hazards:       When heated above flash point, product releases unidentified toxic vapors in addition to carbon monoxide and carbon dioxide.

 

Unusual Fire & Explosion Hazards:      

SECTION 5 – REACTIVITY INFORMATION

 

 

 

 

 

Stable:    X  Unstable:               Hazardous Polymerization:   Occurs:                 Does not Occur:           X

 

Conditions to Avoid:     Avoid static discharge. Flammable vapors can be released at elevated temperatures.

 

Materials to Avoid:       Oxidizing materials.

 

Decomposition Products:          Combustion products of carbon dioxide and carbon monoxide and other unknown gases at high temperatures.

 


Glycol Ether DPM                                                                                                                             Page 2

SECTION 6 – HEALTH HAZARDS – PROTECTIVE MEASURES  – FIRST AID

 
 

 


Carcinogen:      No

 

EYES:              Mild eye irritant. Use chemical goggles when handling this product even though contact is unlikely to cause injury. In the event of contact flush thoroughly with water. Get medical attention if symptoms develop.

 

SKIN:              Low hazard for usual industrial handling Use neoprene or rubber gloves and apron when handling this product. In the event of contact wash thoroughly with soap and water. Get medical attention if symptoms develop.

 

INHALATION:           Low hazard for usual industrial handling. If symptoms occur, remove to fresh air. Get medical attention if necessary.

 

INGESTION:              Low hazard for usual industrial handling. If symptoms occur, get medical advise.

 

IN ALL CASES:          GET PROMPT MEDICAL ATTENTION IF ADVERSE EFFECTS PERSIST

 

PRIMARY ROUTES OF ENTRY:      Skin, eyes, inhalation, ingestion.

 

HYGIENE:      Wash hands and face before eating or drinking. Wash soiled clothing before wearing again if contact occurs.

SECTION 7 – PRECAUTIONS FOR SAFE HANDLING, STORAGE AND USE

 
 

 

 


SPILLS AND LEAKS:            Contain to prevent loss to the environment. Absorb with vermiculite or inert material. Collect excess material. Prevent runoff from entering waterways.

 

STORAGE AND HANDLING:           Keep containers tightly closed. Store away from heat and light. Good ventilation is required for use of this material. Use an approved respirator if fumes are excessive. Do not allow to evaporate to near dryness as explosive peroxides may form.

 

WASTE DISPOSAL:              Follow recommendations of local, state and federal regulations.

 

EMPTY CONTAINERS:        Rinse thoroughly with water. Replace and firmly tighten closures. Send to a recycling center or return to Wausau      Chemical Corporation.

SECTION 8 – REGULATORY INFORMATION

 

 
 

 

 


DOT SHIPPING DESCRIPTION:                  None

 

LABEL REQUIRED                                        None

 

The information contained herein is given in good faith, but no warranty, representation, inducement or license of any kind is made, except that the information is accurate to the best of Wausau Chemical Corporation’s knowledge, or is obtained from sources believed by Wausau Chemical Corporation to be reliable and accurate. Wausau Chemical Corporation does not assume any legal responsibility for use or reliance upon the information being furnished. Customers are encouraged to conduct their own tests. Before using any product, read the container label directions as well as the Material Safety Data Sheet.

 
 

 

 

 

 

 


ND – Not Determined              NA – Not Applicable               NE – Not Established

Print This Page