MATERIAL SAFETY DATA SHEET

 

Wausau Chemical Corporation, 2001 N. River Drive, Wausau, WI 54403

                                                                             Last Revision:              January 27, 2004

HMIS Hazard

4 – Extrem                   Health              2

3 – High                       Fire                  0

2 – Moderate               Reactivity         2

1 – Slight                      Other            OXY

0 - Least

 

 
Emergency       CHEMTREC               800-424-9300

Phones:            Wausau Chemical         715-842-2285

SECTION 1 - MATERIAL IDENTIFICATION

 

 

 
 

 

 


NAME:        HYDROGEN PEROXIDE-50%

SYNONYMS:    Inorganic Peroxide; Hydrogen Dioxide

MANUFACTURED BY:         Interox , Houston TX

SECTION 2  - HAZARDOUS INGREDIENTS

 

 
 

 

 


HAZARDOUS CHEMICAL               CAS #             PERCENT       PEL/TWA        SARA III, SEC 313    

Hydrogen Peroxide                               7722-84-1           50%                 1 ppm                      NO

Water                                                                               50%

Stabilizers                                                                     Trace

SECTION 3 – CHEMICAL AND PHYSICAL PROPERTIES

 
 

 

 


Appearance:           Clear, colorless liquid                      Boiling Point (oF):                                 237 oF

Odor:                     Sharp, pungent odor                       Melting Point (oF):                                -61 oF

pH:                         2.5 to 3.5  (5.0-6.0 for 1%)            Specific Gravity (H2O=1 @ 70oF):       1.195

Water solubility:                        Complete                     Vapor Pressure, mm Hg, 20oC: 18

Vapor Density (air=1)   :           NE                               Volatile Organic (VOC) content:           NA

Evaporation Rate (Butyl Acetate = 1)                <1

SECTION 4 – FIRE AND EXPLOSION HAZARDS

 

 

 

 

 
 

 


Flash Point (Method):               None                Explosive Limits: Lower            None    Upper              None   

Flammable Limits:                     None                Auto Ignition Temperature:        None

Extinguishing Media:                 Water spray.

Special Fire Fighting Procedures and Hazards:  Wear chemical protective clothing and positive pressure self-contained breathing apparatus. Flood any containers with water to cool.

 

Unusual Fire & Explosion Hazards:       Explosion hazard is high for unvented or partially vented containers in a fire. Decomposition of hydrogen peroxide creates oxygen that enhances a fire or explosion hazard. Hydrogen Peroxide is a strong oxidizer that can initiate spontaneous combustion of paper, wood, cloth, and other organic materials. Ignition can be very rapid or can be delayed for up to several hours.

 

SECTION 5 – REACTIVITY INFORMATION

 

 

 

 
 

 


Stable:    X  Unstable:               Hazardous Polymerization:   Occurs:                 Does not Occur:           X

Conditions to Avoid:                 Excessive heat or contamination of any kind.

 

Materials to Avoid:                   Heavy metals and their salts. Reducing agents, strong oxidizers, alkalis and particulate solids. Any organic material. All of these will cause decomposition and formation of oxygen.

 

Decomposition Products:          Oxygen, steam, peroxide vapor and heat.


Hydrogen Peroxide-50%                                                                                                                   Page 2

SECTION 6 – HEALTH HAZARDS – PROTECTIVE MEASURES  – FIRST AID

 
 

 


Carcinogen:      No

EYES:              Severe irritant and corrosive to the eyes with likely corneal damage, especially if not washed immediately. Use chemical goggles when handling this product. In the event of contact flush thoroughly with water for at least 15 minutes. Get medical attention if symptoms develop.

 

SKIN:              Can cause severe skin irritation on contact. Use neoprene or rubber gloves        and apron when handling this product. In the event of contact wash with water for at least 15 minutes. Get medical attention if symptoms develop.

 

INHALATION:           Hazardous. Mist or vapors can cause severe irritation of the respiratory system. Remove to fresh air and get medical help.

 

INGESTION:              Can be toxic. Corrosive to the mouth, esophagus and mucous membranes. Drink large amounts of water. Do Not induce vomiting. Get immediate medical attention. Attempts to evacute the stomach via emesis or gastric lavage should be avoided. A nasogastric or orogastric tube may be required for the reduction of severe distension due to gas formation.

 

IN ALL CASES:          GET PROMPT MEDICAL ATTENTION IF ADVERSE EFFECTS PERSIST

PRIMARY ROUTES OF ENTRY:      Skin, eyes, inhalation, ingestion.

HYGIENE:      Wash hands and face before eating or drinking. Wash soiled clothing before wearing again if contact occurs.

SECTION 7 – PRECAUTIONS FOR SAFE HANDLING, STORAGE AND USE

 
 

 

 


SPILLS AND LEAKS:            Keep untrained personnel out of the area. Use protective clothing to prevent contact with skin or eyes. Dilute with a large volume of water and flush to a sewer or contain until the hydrogen peroxide decomposes. Do not allow concentrated material to enter sewer. DO NOT collect and containerize as contamination will cause decomposition to oxygen and heat.

 

STORAGE AND HANDLING:           Keep containers closed. Do not store in an unvented container. Avoid excessive heat or contamination of any kind. Never return unused material to the original container. Only handle with compatible materials such as glass, stainless steel, aluminum or plastic.

 

WASTE DISPOSAL:              Follow recommendations of local, state and federal regulations.

EMPTY CONTAINERS:        Rinse thoroughly with water. Replace and firmly tighten closures. Send to a recycling center or return to Wausau      Chemical Corporation.

SECTION 8 – REGULATORY INFORMATION

 

 
 

 

 


DOT SHIPPING DESCRIPTION:      Hydrogen Peroxide, aqueous solution, 5.1, UN2014, PG II

LABEL REQUIRED                            Oxidizer

 

The information contained herein is given in good faith, but no warranty, representation, inducement or license of any kind is made, except that the information is accurate to the best of Wausau Chemical Corporation’s knowledge, or is obtained from sources believed by Wausau Chemical Corporation to be reliable and accurate. Wausau Chemical Corporation does not assume any legal responsibility for use or reliance upon the information being furnished. Customers are encouraged to conduct their own tests. Before using any product, read the container label directions as well as the Material Safety Data Sheet.

 
 

 

 

 

 

 


ND – Not Determined              NA – Not Applicable               NE – Not Established

Print This Page